PRODUCT

CENTER

Mechanical Parts (Hitachi)

Category:Linkage Mechanism

Contact Us→Return List→

Technical parameter

Product specification

Technical Requirements/Technical Requiremen

1.  Safety touch panel assembly is suitable for use. 

2.  Assignment Requirements:

A. The safety touch panel protrudes from the door end 30 when walking normally and opening the door. 

B. The full stroke of the safety touch panel is 31±1. 

3.  Action force is 13.7N when clamping out normally, and 5.5N when pulling back 31. 

4.  When the micro switch is activated, the action distance of the safety touch panel is 8±1. 

5.  When packing, care should be taken to protect the surface of the light-transmitting window cover to prevent scratches or damage to its working surface. 

6.  The vibration switch should be set in a normally closed state. 

7.   Plating: Fe/Ep.Zn8.c18 (white zinc plating). 

8.  The dimension without tolerance and the shape and position tolerance without tolerance shall be in accordance with Q/LL8-2000. 

RX size change table
Opening height OPHL1(mm)L2(mm)L3(mm)
OPH=20001985245410
OPH=21002085345510
OPH=22002185445610
OPH=23002285545710
TX size change table
Opening height OPHL1(mm)L2(mm)L3(mm)
OPH=20002015304410
OPH=21002115404510
OPH=22002215504610
OPH=23002315604710